Abstract:
The effects of laser etching, decontamination, and storage treatments on dentin components were studied using Fourier transform (FT)-Raman spectroscopy. Thirty bovine incisors were prepared to expose the dentin surface and then divided in two main groups based upon the decontamination process and storage procedure: autoclaved (group A, n=15) or stored in thymol aqueous solution (group B, n=15). The surfaces of the dentin slices were schematically divided into four areas, with each one corresponding to a treatment subgroup. The specimens were either etched with phosphoric acid (control subgroup) or irradiated with erbium-doped yttrium-aluminum-garnet (Er:YAG) laser (subgroups: I-80 mJ, II-120 mJ, and III-180 mJ, and total energy of 12 J). Samples were analyzed by FT-Raman spectroscopy; we collected three spectra for each area (before and after treatment). The integrated areas of five Raman peaks were calculated to yield average spectra. The areas of the peaks associated with phosphate content (P<0.001), type I collagen, and organic C-H bonds (P<0.05) were reduced significantly in group A (control). Analyses of samples irradiated with reduced laser energies did not show significant changes in the dentin components. These results suggest that thymol storage treatment is advised for in vitro study; furthermore, 12 J of Er:YAG laser energy does not affect dentin components.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...