Pulse oximetry using a disposable finger sensor placed on the forehead in hypoxic patients
Howard A Smithline1, Ned Rudnitzky, Sandy Macomber
1Department of Emergency Medicine, Baystate Medical Center, Springfield, Massachusetts 01199, USA.
Background:
Disposable pulse oximetry sensors designed for the finger are sometimes placed on the forehead. Although finger sensors have not been designed to accurately measure arterial oxygen saturation when placed on other body parts, they are used on the forehead when an oximetry waveform cannot be obtained from the finger.
Objectives:
The purpose of this prospective observational study was to measure the agreement between disposable transmittal sensors placed on the finger and the same sensors placed on the forehead.
Methods:
We used a convenience sample of hypoxic emergency department patients. Patients were attached to three oximeters: 1) a non-disposable finger sensor (reference); 2) a disposable finger sensor placed on the finger; and 3) a disposable finger sensor placed on the forehead. Data were analyzed using the Bland-Altman method. A difference of 5% was considered clinically significant.
Results:
Twenty-five patients were approached, and 20 were enrolled. Eleven of the patients had an absolute difference between the disposable finger sensor placed on the finger compared to the forehead > or = 5%.
Conclusion:
Pulse oximetry measurements taken on the forehead using a disposable finger sensor were inaccurate in over half of the subjects. Therefore, disposable finger oximetry sensors should not be placed on the forehead.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...