Related Experiment Video
Updated: Jun 23, 2026

11:20
Investigation of Early Plasma Evolution Induced by Ultrashort Laser Pulses
Published on: July 2, 2012
Influence of precursor fields on ultrashort pulse autocorrelation measurements and pulse width evolution
Optics Express
|May 7, 2009
Abstract:
The influence of the precursor fields of a double resonance Lorentz model dielectric on ultrashort pulse autocorrelation measurements and the resultant dynamical pulse width evolution is presented.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
Propagation Speed of Electromagnetic Waves
Electromagnetic waves are consistent with Ampere's law. Assuming there is no conduction current Ampere's law is given as:
Effective Value of a Periodic Waveform
The concept of effective value, the root mean square (RMS) value, is crucial in understanding electrical circuits and power delivery. This idea emerges from the necessity to measure the effectiveness of a voltage or current source in supplying power to a resistive load.
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Voltammetric Techniques: Pulse Voltammetry
Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
Voltammetry: Factors Affecting Measurements
A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
Induced Electric Fields: Applications
An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...

