Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
Detection of low-frequency oscillations in renal blood flow
1Department of Biomedical Engineering, SUNY Stony Brook, Stony Brook, New York 11794-8181, USA.
Abstract:
Detection of the low-frequency (LF; approximately 0.01 Hz) component of renal blood flow, which is theorized to reflect the action of a third renal autoregulatory mechanism, has been difficult due to its slow dynamics. In this work, we used three different experimental approaches to detect the presence of the LF component of renal autoregulation using normotensive and spontaneously hypertensive rats (SHR), both anesthetized and unanesthetized. The first experimental approach utilized a blood pressure forcing in the form of a chirp, an oscillating perturbation with linearly increasing frequency, to elicit responses from the LF autoregulatory component in anesthetized normotensive rats. The second experimental approach involved collection and analysis of spontaneous blood flow fluctuation data from anesthetized normotensive rats and SHR to search for evidence of the LF component in the form of either amplitude or frequency modulation of the myogenic and tubuloglomerular feedback mechanisms. The third experiment used telemetric recordings of arterial pressure and renal blood flow from normotensive rats and SHR for the same purpose. Our transfer function analysis of chirp signal data yielded a resonant peak centered at 0.01 Hz that is greater than 0 dB, with the transfer function gain attenuated to lower than 0 dB at lower frequencies, which is a hallmark of autoregulation. Analysis of the data from the second experiments detected the presence of approximately 0.01-Hz oscillations only with isoflurane, albeit at a weaker strength compared with telemetric recordings. With the third experimental approach, the strength of the LF component was significantly weaker in the SHR than in the normotensive rats. In summary, our detection via the amplitude modulation approach of interactions between the LF component and both tubuloglomerular feedback and the myogenic mechanism, with the LF component having an identical frequency to that of the resonant gain peak, provides evidence that 0.01-Hz oscillations may represent the third autoregulatory mechanism.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies VII: Vascular Imaging
Nursing Assessment of the Genitourinary System III: Percussion and Auscultation
Renal Corpuscle
Glomerulus: Structure and Function
The glomerulus is a tiny, intricate network of capillaries located at the beginning of the nephron. It's enveloped by the Bowman's capsule and receives its blood supply from an afferent arteriole, which divides into numerous capillaries...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration