Related Experiment Video
Updated: Jun 23, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography
Harald Seifarth1, Michael Puesken, John F Kalafut
1Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Strasse 33, 48149 Muenster, Germany. seifarth@uni-muenster.de
Abstract:
The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9 + or - 49.9)-396.1(+ or - 52.1) HU vs. 366.0(+ or - 64.3)-341.6(+ or - 72.5) HU; LAD: 398.9(+ or - 48.6)-364.6(+ or - 44.6) HU vs. 356.3(+ or - 69.5)-323.0(+ or - 67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(+ or - 52.1) vs. 370.7(+ or - 70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
14:24Percutaneous Contrast Echocardiography-guided Intramyocardial Injection and Cell Delivery in a Large Preclinical Model
Published on: January 21, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation I: X-ray and CT
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...