Related Experiment Video
Updated: Jun 23, 2026

Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
Variation patterns of nitric oxide in Catalonia during the period from 2001 to 2006 using multivariate data analysis
M Alier1, M Felipe-Sotelo, I Hernàndez
1Department of Environmental Chemistry, IIQAB-CSIC, C/Jordi Girona Salgado, 18-26, 08034 Barcelona, Spain.
Abstract:
Multivariate data analysis methods are applied to study of the geographical and temporal distribution of nitric oxide (NO) in Catalonia (North-East Spain), measured during the period 2001-2006 in 50 sampling stations. Principal component analysis (PCA) and Multivariate Curve Resolution Alternating Least Squares (MCR-ALS) were applied for that purpose. The simultaneous analysis of NO data from sampling stations showed that its geographical distribution was rather uniform during the period considered. When three individual sampling stations were considered (two urban sites and one rural location), three different temporal patterns were resolved, with marked daily-night changes mainly attributed to traffic and also, important winter-summer seasonal variations. A decreasing trend in the levels of NO has been also observed in recent years. Comparison with nitrogen dioxide (NO(2)) profiles shows that the daily variation is quite similar to the NO variation, however NO(2) displays very little oscillations along the seasons and no reduction of its concentration was observed in the last years, contrasting with NO tendencies. The use of MCR-ALS is confirmed to be a useful method to improve interpretability in atmospheric contamination studies. The use of non-negativity and trilinearity constraints is shown to provide improved interpretations of the different contamination patterns in environmental terms.
Related Concept Videos
Nitric Oxide Signaling Pathway
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This relationship...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
The Nitrogen Cycle
Statistical Methods for Analyzing Epidemiological Data