Comparison of ambulatory blood pressure reference standards in children evaluated for hypertension
Deborah P Jones1, Phyllis A Richey, Bruce S Alpert
1Department of Pediatrics, University of Tennessee Health Science Center, Memphis, Tennessee 38103, USA. dpjones@utmem.edu
Insights
Standardizing ambulatory blood pressure monitoring (ABPM) in children is crucial. Different reference standards can alter hypertension classification in approximately 5% of pediatric cases.
Area of Science:
- Pediatric Cardiology
- Clinical Hypertension Research
- Biomedical Data Analysis
Background:
- Accurate blood pressure measurement in children is vital for diagnosing and managing hypertension.
- Ambulatory blood pressure monitoring (ABPM) provides valuable data for assessing blood pressure patterns over time.
- Standardization of ABPM data is essential for consistent interpretation and clinical decision-making.
Purpose of the Study:
- To systematically compare different standardization methods for ambulatory blood pressure monitoring (ABPM) data in a pediatric cohort.
- To evaluate the impact of using original versus modified reference standards on blood pressure classification in children.
- To assess the agreement between various standardization approaches for pediatric ABPM.
Main Methods:
- Calculated blood pressure indices, loads, and standard deviation scores using both original and modified ABPM reference standards.
- Employed Bland-Altman plots to assess the agreement in blood pressure measurements between standardization methods.
- Utilized kappa statistics to quantify the level of agreement in hypertension classification based on different standards.
Main Results:
- Excellent overall agreement was observed between the two standardization methods for ABPM data.
- A notable discrepancy was found in approximately 5% of children, who were classified differently regarding their blood pressure status (hypertension vs. normal).
- The choice of reference standards significantly influenced the classification of individual children's blood pressure levels.
Conclusions:
- The interpretation of pediatric ABPM data can vary depending on the specific version of the German Working Group's reference standards used.
- Clinicians must be aware of potential classification discrepancies when applying different standardization methods for ABPM in children.
- Careful selection and consistent application of reference standards are necessary for accurate hypertension diagnosis in pediatric populations.
Objective:
The purpose of this study was to systematically compare methods for standardization of blood pressure levels obtained by ambulatory blood pressure monitoring (ABPM) in a group of 111 children studied at our institution.
Methods:
Blood pressure indices, blood pressure loads and standard deviation scores were calculated using the original ABPM and the modified reference standards. Bland-Altman plots and kappa statistics for the level of agreement were generated.
Results:
Overall, the agreement between the two methods was excellent; however, approximately 5% of children were classified differently by one as compared with the other method.
Conclusion:
Depending on which version of the German Working Group's reference standards is used for interpretation of ABPM data, the classification of the individual as having hypertension or normal blood pressure may vary.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hypertension III: Clinical Manifestations and Diagnostic Studies