[Study on stray light in self-reversal background correction for atomic absorption spectrometry--the properties of
Yao-Han Liu1, Zhi-Gao Liu, Zhi Zhou
1Shanghai Spectrum Instruments Limited Company, Shanghai 200233, China. liuyh401302@sina.com
Abstract:
In self-reversal background correction the particularity of stray light that is not absorbed by the sample matrix is different from that in deuterium lamp and Zeeman background correction. The stray light is evaluated using the cut-off solution method and its effects were studied by means of simulation background absorption using potassium dichromate solution molecular absorption. Experiments confirmed that the stray light due to light source for the sample beam (Conventional pulse, low Current) and reference beam (narrow pulse, high current) is obviously different, with the former being higher than the latter. Therefore, the difference is an important source in self-reversal background correction errors and the errors can not be ignored in high background correction. The present paper also showed the relationships among stray light and lamp current, light energy, and spectral bandwidth. The results show that the ratio of stray light is much related to the lamp current, and the larger the lamp current, the smaller the ratio of stray light. The ratio of stray light that changes with lamp current is not directly related to the energy of analytical line. Stray light ratio decreases with the decrease in spectral bandwidth and its character is similar to continuous spectrum.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...