Abstract:
Bronchoscopy and bronchial suctioning during intra-operative artificial ventilation often causes leakage from the ventilation circuit with a decrease in ventilatory parameters and possible workplace contamination with anaesthetic gases. Different connectors have been developed to reduce gas leakage. We evaluated the following connectors : VBM 2 mm, 3 mm and 5 mm, Bodai Suction-Safe, Bodai Bronch-Safe and Bodai Trach-Safe, as well as the BE 105-7, BE 105-8 and SH 7-45. Invasive bronchial instruments (catheters, bronchoscopes and bronchial blockers) with 1.67-7.33 mm diameter were used. Pressure-controlled ventilation was performed on a test lung using a ventilator. Sevoflurane concentration in the room was measured 0.2 and 1.5 m from the connector using a photo-acoustic infrared-spectroscope. The VBM connectors caused the least gas leak and ensured stability of ventilation parameters even at peak pressures when combined with smaller instruments. With instruments > 6 mm, BE 105-7, BE 105-8 and SH 7-45 connectors performed best. The Bodai connectors showed a reduced ability to prevent leakage and to keep ventilatory parameters stable. All connectors, excluding the Bodai Trach-Safe, prevented exposure to anaesthetic gases beyond the current safety recommendations when combined with the fitting instruments. The connectors showed different ranges of tightness, equivalent to different ranges of compatibility with the instruments used.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Tracheostomy Suctioning II: Procedure