Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
Properties of the z-Transform I01:17

Properties of the z-Transform I

The z-transform is a fundamental tool in digital signal processing, enabling the analysis of discrete-time systems through its various properties. It is an invaluable tool for analyzing discrete-time systems, offering a range of properties that simplify complex signal manipulations. One fundamental property is linearity. For any two discrete-time signals, the z-transform of their linear combination equals the same linear combination of their individual z-transforms. This property is essential...
Downsampling01:20

Downsampling

When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
Inverse z-Transform by Partial Fraction Expansion01:20

Inverse z-Transform by Partial Fraction Expansion

The inverse z-transform is a crucial technique for converting a function from its z-domain representation back to the time domain. One effective method for finding the inverse z-transform is the Partial Fraction Method, which involves decomposing a function into simpler fractions with distinct coefficients. These fractions correspond to known z-transform pairs, facilitating the inverse transformation process.
To begin the process, the poles of the function are identified and the function is...
Region of Convergence01:17

Region of Convergence

The z-transform is a powerful mathematical tool used in the analysis of discrete-time signals and systems. It is a crucial tool in the analysis of discrete-time systems, but its convergence is limited to specific values of the complex variable z. This range of values, known as the Region of Convergence (ROC), is fundamental in determining the behavior and stability of a system or signal. The ROC defines the region in the complex plane where the z-transform converges, which can take various...
Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Benchmarking the Robustness of Autonomous Driving to Environmental Illusions: A Lane Perception Perspective.

IEEE transactions on pattern analysis and machine intelligence·2026
Same author

Holistic Invariant Retracing for Distortion-Resilient Multi-Modal Learning in Spatial Transcriptomics.

IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026
Same author

Demonstration of efficient predictive surrogates for large-scale quantum processors.

Nature communications·2026
Same author

A DeepSeek-powered AI system for automated chest radiograph interpretation in clinical practice.

Nature communications·2026
Same author

NoisePO: Efficient Semantic Noise Generation and Ranking for Diffusion-Based Text-to-Image Synthesis.

IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026
Same author

Stability and Generalization for Distributed SGDA.

IEEE transactions on pattern analysis and machine intelligence·2026
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Jun 23, 2026

Blood Flow Imaging with Ultrafast Doppler
05:57

Blood Flow Imaging with Ultrafast Doppler

Published on: October 14, 2020

Reduced-reference IQA in contourlet domain.

Dacheng Tao1, Xuelong Li, Wen Lu

  • 1School of Computer Engineering, Nanyang Technological University, Singapore. dctao@ntu.edu.sg

IEEE Transactions on Systems, Man, and Cybernetics. Part B, Cybernetics : a Publication of the IEEE Systems, Man, and Cybernetics Society
|May 22, 2009
PubMed
Summary

This study introduces a new reduced-reference image quality assessment (RR-IQA) method. It effectively mimics the human visual system (HVS) for accurate image quality evaluation.

More Related Videos

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

Related Experiment Videos

Last Updated: Jun 23, 2026

Blood Flow Imaging with Ultrafast Doppler
05:57

Blood Flow Imaging with Ultrafast Doppler

Published on: October 14, 2020

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

Area of Science:

  • Computer Vision
  • Image Processing
  • Human-Computer Interaction

Background:

  • The human visual system (HVS) is crucial for accurate image quality assessment (IQA).
  • Existing reduced-reference (RR) IQA methods require improvement in mimicking HVS non-linearities.
  • Developing objective IQA metrics that align with subjective perception remains a challenge.

Purpose of the Study:

  • To propose a novel reduced-reference image quality assessment (RR-IQA) scheme.
  • To enhance IQA by integrating contourlet transform, contrast sensitivity function (CSF), and Weber's law of just noticeable difference (JND).
  • To develop an objective IQA method that closely correlates with human subjective perception.

Main Methods:

  • Utilized contourlet transform to decompose images and extract features, mimicking the HVS multichannel structure.
  • Applied contrast sensitivity function (CSF) to weight contourlet coefficients, simulating HVS nonlinearities.
  • Incorporated Weber's law of just noticeable difference (JND) to model sensory perception variations.

Main Results:

  • The proposed RR-IQA scheme demonstrated strong consistency with subjective mean opinion scores.
  • Empirical studies on the LIVE database validated the objective assessment results.
  • The developed framework effectively reflects the visual quality of images as perceived by humans.

Conclusions:

  • The novel RR-IQA scheme effectively leverages contourlet transform, CSF, and JND.
  • The proposed method shows excellent agreement with subjective visual quality perception.
  • This approach offers a robust objective measure for image quality assessment aligned with HVS.