Related Experiment Video
Updated: Jun 23, 2026

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Influence of computer-aided detection false-positives on reader performance and diagnostic confidence for CT
Stuart A Taylor1, John Brittenden, James Lenton
1Department of Specialist Imaging, University College Hospital, London, United Kingdom. csytaylor@yahoo.co.uk
Objective:
The objective of our study was to investigate whether an increasing number of computer-aided detection (CAD) false-positives decreases reader sensitivity, specificity, and confidence for nonexpert readers of CT colonography (CTC).
Materials And Methods:
Fifty CTC data sets (29 men; mean age, 65 years), 25 of which contained 35 polyps > or = 5 mm, were selected in which CAD had 100% polyp sensitivity at two sphericity settings (0 and 75) but differed in the number of false-positives. The data sets were read by five readers twice: once at each sphericity setting. Sensitivity, specificity, report time, and confidence before and after second-read CAD were compared using the paired exact and Student's t test, respectively. Receiver operating characteristic (ROC) curves were generated using reader confidence (1-100) in correct case classification (normal or abnormal).
Results:
CAD generated a mean of 42 (range, 3-118) and 15 (range, 1-36) false-positives at a sphericity of 0 and 75, respectively. CAD at both settings increased per-patient sensitivity from 82% to 87% (p = 0.03) and per-polyp sensitivity by 8% and 10% for a sphericity of 0 and 75, respectively (p < 0.001). Specificity decreased from 84% to 79% (sphericity 0 and 75, p = 0.03 and 0.07). There was no difference in sensitivity, specificity, or reader confidence between sphericity settings (p = 1.0, 1.0, 0.11, respectively). The area under the ROC curve was 0.78 (95% CI, 0.70-0.86) and 0.77 (0.68-0.85) for a sphericity of 0 and 75, respectively. CAD added a median of 4.4 minutes (interquartile range [IQR], 2.7-6.5 minutes) and 2.2 minutes (IQR, 1.2-4.0 minutes) for a sphericity of 0 and 75, respectively (p < 0.001). CONCLUSION. CAD has the potential to increase the sensitivity of readers inexperienced with CTC, although specificity may be reduced. An increased number of CAD-generated false-positives does not negate any beneficial effect but does reduce efficiency.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT