X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Loss of image quality due to the image output of a digital radiographic system]
Kerstin Jungnickel1, Ulf Redlich
1Klinik für Radiologie und Nuklearmedizin, Universitätsklinikum Magdeburg. kerstin.jungnickel@med.ovgu.de
Abstract:
Not all digital radiography systems allow an unrestricted image postprocessing for the radiologist. Depending on the X-ray system there are restrictions in varying brightness and contrast of the image. We compared grey level information that are given to the radiologist by various digital radiography systems. Histograms of differently postprocessed X-ray images were calculated, which were acquired by three different X-ray systems. We found that every modality has its own way of saving and converting the images into DICOM data. The processed image is either sent into PACS with the initial grey level range (10 or 12 bit) or the image is sent with a reduced grey level range due to windowing. The grey level range is associated with the ability of unrestricted windowing in PACS. So, taking an image with a reduced grey level range, the radiologist will face limited potential to optimise the window setting individually afterwards. The loss of image quality due to image transfer from the modality to PACS can lead to an information loss in the diagnostic relevant range.
Related Concept Videos
X-ray Imaging
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Radiological Investigation I: X-ray and CT
Determination of Crystal Structures