Related Experiment Video
Updated: Jun 23, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
What is the optimal interval between successive home blood pressure readings using an automated oscillometric device?
Kazuo Eguchi1, Sujith Kuruvilla, Gbenga Ogedegbe
1Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University, Tochigi, Japan. ke112@jichi.ac.jp
Objectives:
To clarify whether a shorter interval between three successive home blood pressure (HBP) readings (10 s vs. 1 min) taken twice a day gives a better prediction of the average 24-h BP and better patient compliance.
Design:
We enrolled 56 patients from a hypertension clinic (mean age: 60 +/- 14 years; 54% female patients). The study consisted of three clinic visits, with two 4-week periods of self-monitoring of HBP between them, and a 24-h ambulatory BP monitoring at the second visit. Using a crossover design, with order randomized, the oscillometric HBP device (HEM-5001) could be programmed to take three consecutive readings at either 10-s or 1-min intervals, each of which was done for 4 weeks. Patients were asked to measure three HBP readings in the morning and evening. All the readings were stored in the memory of the monitors.
Results:
The analyses were performed using the second-third HBP readings. The average systolic BP/diastolic BP for the 10-s and 1-min intervals at home were 136.1 +/- 15.8/77.5 +/- 9.5 and 133.2 +/- 15.5/76.9 +/- 9.3 mmHg (P = 0.001/0.19 for the differences in systolic BP and diastolic BP), respectively. The 1-min BP readings were significantly closer to the average of awake ambulatory BP (131 +/- 14/79 +/- 10 mmHg) than the 10-s interval readings. There was no significant difference in patients' compliance in taking adequate numbers of readings at the different time intervals.
Conclusion:
The 1-min interval between HBP readings gave a closer agreement with the daytime average BP than the 10-s interval.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...