Inhaled gases humidification and heating during artificial ventilation with low flow and minimal fresh gases flow
Susane Bruder Silveira Gorayb1, José Reinaldo Cerqueira Braz, Regina Helena Garcia Martins
1Hospital das Clínicas (HC) do CET/SBA do Departamento de Anestesiologia da Faculdade de Medicina de Botucatu (FMB), UNESP, Botucatu, SP.
Background And Objectives:
Inhaled gas humidification and heating are necessary in patients under tracheal intubation or tracheostomy to prevent damage to respiratory system resulting from the contact of cold and dry gas with the airways. This study aimed at evaluating the effect of respiratory circle systems with carbon dioxide absorbers from Dräger's Cicero anesthesia machine (Germany) as to inhaled gases heating and humidification ability using low fresh gases flow (1 L min(-1)) or minimum flow (0.5 L min(-1)).
Methods:
Participated in this study, 24 patients, physical status ASA I, aged 18-65 years, submitted to general anesthesia using Dräger's Cicero workstation (Germany) for abdominal surgery, who were randomly distributed in two groups: low flow group (LF) received 0.5 L min(-1) oxygen and 0.5 L min(-1) nitrous oxide, and minimum flow group (MF) received 0.5 L min(-1) oxygen only. Evaluated attributes were temperature, relative and absolute humidity of the operating room and of respiratory circuit gas.
Results:
There were no significant differences in inhaled gas temperature, relative and absolute humidity between groups, but they have increased along time in both groups, with influence of operating room temperature on inhaled gas temperature for both groups. Near optimal levels of humidity and temperature were reached as from 90 minutes in both groups.
Conclusions:
There have been no significant differences in inhaled gas humidity and temperature with fresh gases low flow or minimum flow.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...