Related Experiment Video
Updated: Jun 22, 2026

Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
[Continuous and bolus thermodilution cardiac output measurement during off-pump coronary artery bypass surgery.]
Sílvia M Kim1, Sílvia D S Oliveira, Ubirajara S Fonseca
1FM, USP.
Background And Objectives:
Off-pump CABG surgery is related to major and abrupt hemodynamic changes that may not be immediately detected by continuous cardiac output measurement (CCO). This study aimed at comparing results of cardiac index measurement with pulmonary artery catheter (PAC) with thermal filament (Baxter Edwards Critical Care, Irvine, CA) versus standard bolus thermodilution method during distal coronary anastomosis.
Methods:
Participated in this study 10 patients undergoing off-pump CABG who were monitored with PAC with thermal filament. Measurements of cardiac index were obtained in four moments: at anesthetic induction with the chest still closed (M1), after sternotomy (M2), after heart stabilization with the octopus device (M3) and at distal anastomosis completion (M4).
Results:
There has been significant cardiac index decrease (p < 0.05) during coronary anastomosis, detected when measurements were taken with bolus thermodilution method. Cardiac index has varied 2.8 +/- 0.7 to 2.3 +/- 0.8 L.min.m-2 in the beginning and 2.5 +/- 0.8 L.min.m-2 at the end of anastomosis. This variation was not detected by the continuous method (from 3 +/- 0.6 to 3.2 +/- 0.5 to 3.1 +/- 0.6 L.min.m-2 during anastomosis).
Conclusions:
CCO measurement with PAC was late in detecting acute hemodynamic changes due to changes in heart position during off-pump CABG.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...