Related Experiment Video
Updated: Jun 22, 2026

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
Flow visualization study of a novel respiratory assist catheter
Stephanus G Budilarto1, Brian J Frankowski, Brack G Hattler
1Department of Chemical Engineering, University of Pittsburgh, Pittsburgh, PA, USA.
Abstract:
Respiratory assist using intravenous catheters may be a potential therapy for patients with acute and acute-on-chronic lung failure. An important design constraint is respiratory catheter size, and new strategies are needed that enable size reduction while maintaining adequate gas exchange. Our group is currently developing a percutaneous respiratory assist catheter (PRAC) that uses a rotating bundle of hollow fiber membranes to enhance CO(2) removal and O(2) supply with increasing bundle rotation rate. In this study, particle image velocimetry (PIV) was used to analyze the fluid flow patterns and velocity fields surrounding the rotating fiber bundle of the PRAC. The goal of the study was to assess the rotational flow patterns within the context of the gas exchange enhancement that occurs with increasing fiber bundle rotation. A PRAC prototype was placed in a 1-in. internal diameter test section of an in vitro flow loop designed specifically for PIV studies. The rotation rate of the PRAC was varied between 500 and 7000 rpm, and PIV was used to determine the velocity fields in the primary (r-theta) and secondary (r-z) flow planes. The secondary flow exhibited time-varying and incoherent vortices that were consistent with the classical Taylor vortices expected for Taylor numbers (Ta) corresponding to the rotation speeds studied (2200 < Ta < 31 000). In the primary flow, the tangential velocity exhibited boundary layers of less than (1/2) mm adjacent to the fiber bundle and vessel wall. The estimated shear stress associated with the Taylor vortices was approximately 11 dyne/cm(2) at 7000 rpm and was over 10 times smaller than the shear stress in the primary flow boundary layers.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...