Related Experiment Video
Updated: Jun 22, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Parametric versus nonparametric transfer function estimation of cerebral autoregulation from spontaneous
Michael Jachan1, Matthias Reinhard, Linda Spindeler
1Center for Data Analysis and Modeling (FDM), Freiburg University, Eckerstr. 1/FDM, 79104 Freiburg, Germany. michael.jachan@fdm.uni-freiburg.de
Abstract:
Cerebral autoregulation (CAR) is a control mechanism of the brain keeping cerebral blood flow constant albeit the arterial blood pressure varies. Impaired CAR may be associated with an increased risk of cerebral ischemic events in patients with obstructive cerebrovascular disease. Spontaneous blood pressure oscillations are analyzed using a nonparametric and two parametric transfer function estimators, i.e. the autoregressive-moving-average model with exogenous inputs or the vector-autoregressive model. Performance of the methods was compared using data from patients with unilateral stenosis or occlusion. We also analyzed reproducibility by comparing partitions of the data an with data from other patients which have been measured twice. Results show that there is no significant difference between methods (ANOVA, p > 0.27), and that CAR measurements can be performed reproducibly (Kendall's tau, p < 0.0016) by all three methods. In conclusion, CAR measurements by means of spontaneous oscillations can be obtained stably and the presented parametric approaches can serve for future online application of CAR measurement.
Related Concept Videos
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...

