Investigation of chemometric instrumental transfer methods for high-resolution NMR
Todd M Alam1, M Kathleen Alam, Sarah K McIntyre
1Department of Electronic and Nanostructured Materials, Sandia National Laboratories, Albuquerque, New Mexico 87185-0886, USA. tmalam@sandia.gov
Abstract:
The implementation of direct standardization (DS), piecewise direct standardization (PDS), and double-window piecewise direct standardization (DWPDS) instrumental transfer techniques for high-resolution (1)H NMR spectral data was explored. The ability to transfer a multivariate calibration model developed for a "master or target" NMR instrument configuration to seven different ("secondary") NMR instrument configurations was measured. Partial least-squares (PLS) calibration of glucose, glycine, and citrate metabolite relative concentrations in model mixtures following mapping of the secondary instrumental configurations using DS, PDS, or DWPDS instrumental transfer allowed the performance of the different transfer methods to be assessed. Results from these studies suggest that DS and PDS transfer techniques produce similar improvements in the error of prediction compared to each other and provide a significant improvement over standard spectral preprocessing techniques including reference deconvolution and spectral binning. The DS instrumental transfer method produced the largest percent improvement in the predictions of concentrations for these model mixtures but, in general, required that additional transfer calibration standards be used. Limitations of the different instrumental transfer methods with respect to sample subset selection are also discussed.
More Related Videos
09:01Metabolomic Analysis of Rat Brain by High Resolution Nuclear Magnetic Resonance Spectroscopy of Tissue Extracts
Published on: September 21, 2014
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
2D NMR: Overview of Heteronuclear Correlation Techniques
High-Resolution Mass Spectrometry (HRMS)
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
NMR Spectrometers: Resolution and Error Correction