Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
Published on: July 17, 2015
Backscattered electron imaging for high resolution surface scanning electron microscopy with a new type YAG-detector
1Integrated Microscopy Resource for Biomedical Research, University of Wisconsin-Madison 53706.
Summary
A new double layer coating method enhances high-resolution scanning electron microscopy (SEM) imaging of biological samples. Optimizing accelerating voltage (Vo) improved contrast for backscattered electron (BSE) imaging, revealing detailed 3D structures.
Area of Science:
- Microscopy
- Biological Imaging
- Materials Science
Background:
- High-resolution scanning electron microscopy (SEM) of large biological samples requires specialized coating and imaging techniques.
- Backscattered electron (BSE) imaging of thin metal coatings yields low signals, necessitating field emission SEMs and sensitive BSE detectors.
- Previous methods struggled with contrast for certain sample types, limiting detailed structural analysis.
Purpose of the Study:
- To improve the double layer coating method for enhanced backscattered electron (BSE) imaging in high-resolution SEM.
- To investigate the impact of coating techniques and accelerating voltage (Vo) on image contrast and resolution.
- To demonstrate the potential of an improved BSE detector and field emission SEM for biological sample analysis.
Main Methods:
- Utilized an improved YAG-type BSE detector with an in-lens field emission SEM.
- Prepared cryo-samples: cultured kidney cells coated with platinum-carbon and carbon; and Paramecium trichocyst matrixes coated with platinum and carbon.
- Varied coating methods (unidirectional shadowing, rotation/tumbling sputtering) and primary beam accelerating voltage (Vo) from 4 kV to 10 kV.
Main Results:
- High contrast was achieved for unidirectionally coated kidney cells at Vo ≥ 10 kV.
- Trichocyst matrixes with uniform platinum coating showed poor contrast at higher Vo due to reduced BSE signal from the thin layer.
- Lowering Vo to 4 kV significantly improved contrast for trichocyst matrixes by increasing BSE scattering from the platinum layer.
Conclusions:
- Optimizing accelerating voltage (Vo) is crucial for achieving good contrast in BSE imaging with double layer coatings.
- The improved BSE detection method provides high-resolution, 3D structural information comparable to transmission electron microscopy but with better overall visualization.
- This approach offers a valuable tool for detailed analysis of biological ultrastructures, such as the globular particles and fibrous connections in trichocyst matrixes.
More Related Videos
Related Concept Videos
Overview of Electron Microscopy
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Scanning Electron Microscopy
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
Transmission Electron Microscopy
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400 keV in...
Preparation of Samples for Electron Microscopy
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
Overview of Microscopy Techniques
The early pioneers of microscopy opened a window into the invisible world of microorganisms. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes that leveraged nonvisible light, such as fluorescence microscopy that uses an ultraviolet light source and electron microscopy that uses short-wavelength electron beams. These advances significantly improved magnification, image resolution, and contrast. By comparison, the...