Related Experiment Video
Updated: Jun 22, 2026

A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting
Published on: March 9, 2017
Synthesis, properties, and live-cell imaging studies of luminescent cyclometalated iridium(III) polypyridine
Kenneth Yin Zhang1, Kenneth Kam-Wing Lo
1Department of Biology and Chemistry, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong, People's Republic of China.
Abstract:
Three luminescent cyclometalated iridium(III) bis-biotin complexes [Ir(N(wedge)C)(2)(N(wedge)N)](PF(6)) (HN(wedge)C = 2-(4-(N-(6-(biotinamido)hexyl)aminomethyl)phenyl)pyridine, HppyC6B, N(wedge)N = 2,2'-bipyridine, bpy (1); HN(wedge)C = 2-phenylpyridine, Hppy, N(wedge)N = 4,4'-bis((2-(biotinamido)ethyl)aminocarbonyl)-2,2'-bipyridine, bpyC2B2 (2); HN(wedge)C = Hppy, N(wedge)N = 4,4'-bis((2-((6-(biotinamido)hexanoyl)amino)ethyl)aminocarbonyl)-2,2'-bipyridine, bpyC2C6B2 (3)) and one tris-biotin complex [Ir(ppyC6B)(2)(bpyC6B)](PF(6)) (bpyC6B = 4-((6-(biotinamido)hexyl)aminocarbonyl)-4'-methyl-2,2'-bipyridine) (4) have been synthesized and characterized. The biotin-free complex [Ir(ppy)(2)(bpyC4)](PF(6)) (bpyC4 = 4,4'-bis(n-butylaminocarbonyl)-2,2'-bipyridine) (5) has also been prepared for comparison studies. Upon photoexcitation, all the complexes displayed intense and long-lived greenish-yellow to red triplet metal-to-ligand charge-transfer ((3)MLCT) (dpi (Ir) --> pi*(N(wedge)N)) emission in fluid solutions at room temperature and in low-temperature glass. Cyclic voltammetric studies revealed iridium(IV/III) oxidation at about +1.21 to + 1.29 V and diimine-based reductions at about -1.07 to -1.39 V versus SCE. The interactions of the bis-biotin and tris-biotin complexes with avidin have been studied by 4'-hydroxyazobenzene-2-carboxylic acid (HABA) assays, emission titrations, and dissociation assays. The possibility of these complexes as cross-linkers for avidin has been examined by microscopy studies using avidin-conjugated green fluororescent microspheres and size-exclusion HPLC analysis. Utilization of these luminescent iridium(III) biotin complexes in signal amplification has been demonstrated using avidin-coated nonfluorescent microspheres and complex 3 as an example. Additionally, the lipophilicity of all the complexes has been determined by reversed-phase HPLC. The cytotoxicity of these iridium(III) complexes toward the human cervix epithelioid carcinoma (HeLa) cell line has been evaluated by 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyltetrazolium bromide (MTT) assays. Furthermore, the cellular uptake of the complexes has been examined by ICP-MS, laser-scanning confocal microscopy, and flow cytometry.
Related Concept Videos
Photoluminescence: Applications
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...

