24-h blood pressure in Space: The dark side of being an astronaut
John M Karemaker1, Janneke Berecki-Gisolf
1Department of Systems Physiology, Academic Medical Center at the University of Amsterdam, The Netherlands. j.m.karemaker@amc.uva.nl
Abstract:
Inflight 24-h profiles of blood pressure (BP) and heart rate (HR) were recorded in 2 ESA-astronauts by automatic upper arm cuff measurements. In one astronaut this was combined with Portapres continuous finger blood pressure recordings. It was the intention to contrast the latter to 24-h recordings in an earlier Head-Down-Tilted (HDT) bed rest study [Voogel, A.J., Stok, W.J., Pretorius, P.J., Van Montfrans, G.A., Langewouters, G.J., Karemaker, J.M., 1997. Circadian blood pressure and systemic haemodynamics during 42 days of 6 degrees head-down tilt. Acta Physiol. Scand. 161, pp. 71-80]. BP-levels in Space were not very much changed from preflight; the circadian BP-rhythm seemed dampened. Only daytime diastolic pressures (both subjects) and nighttime HR (one subject) were significantly lower in Space. However, compared to the effect of a control tilt manoeuvre on the ground, even lower BP values might have been expected. Striking were the BP- and HR-surges during the working days in Space, often related to stressful moments like live appearances on public TV. Systemic vascular resistance (SVR) dropped during the night, unlike HDT. Thus, actual spaceflight refuted our earlier findings in HDT both for BP-levels and for daytime to nighttime changes. The combined observations lead to the hypothesis that short-lasting spaceflight may induce strong psychological stress in astronauts. When interpreting space-physiological observations this must be taken into account.
Related Concept Videos
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the diastolic...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: