Assessment of diastolic dysfunction in elderly hypertensive patients using integrated Doppler echocardiography
Mónika Dénes1, István Kiss, Mária Lengyel
1Gottsegen György Hungarian Institute of Cardiology, Budapest, Budapest, Hungary.
Insights
Many elderly hypertensive patients have asymptomatic diastolic dysfunction (DD). Advanced echocardiography, including Tissue Doppler imaging (TDI) and Pulmonary venous (PV) flow, helps detect elevated filling pressures even with normal mitral inflow patterns.
Area of Science:
- Cardiology
- Echocardiography
- Diastolic Function Assessment
Background:
- Elderly hypertensive patients with preserved systolic function may have undiagnosed diastolic dysfunction (DD).
- Routine echocardiography might not fully capture the nuances of diastolic function in this population.
- Tissue Doppler imaging (TDI) and Pulmonary venous (PV) flow assessment can provide additional insights.
Purpose of the Study:
- To assess stages of diastolic dysfunction (DD) in elderly, asymptomatic, hypertensive patients with preserved systolic function.
- To investigate the utility of TDI and PV flow in routine echocardiography for evaluating diastolic function.
- To identify prevalence of elevated filling pressures (EFP) in this cohort.
Main Methods:
- 322 elderly hypertensive patients (age 70.8±9.1 years) with preserved systolic function were enrolled.
- Diastolic function was evaluated using mitral inflow patterns, TDI (Ea: early diastolic velocity), and PV flow.
- Elevated filling pressure (EFP) was defined by specific criteria including deceleration time, E/Ea ratio, and PV flow S/D ratio.
Main Results:
- Moderate-to-severe DD was found in approximately one-third of patients (109/322).
- Early diastolic velocity (Ea) was significantly decreased in patients with mild and moderate DD compared to those without DD.
- 58% of patients with a normal mitral inflow pattern exhibited elevated filling pressures (EFP).
Conclusions:
- A significant proportion of elderly hypertensive patients with preserved systolic function have moderate-to-severe asymptomatic diastolic dysfunction.
- TDI and PV flow assessment are valuable additions to routine echocardiography for detecting elevated filling pressures.
- Elevated filling pressures can be present even in the presence of a normal mitral inflow pattern, highlighting the need for advanced assessment.
Unlabelled:
The aim of this study was to assess the different stages of diastolic dysfunction (DD) in elderly, asymptomatic, hypertensive patients with preserved systolic function, and to investigate the role of Tissue Doppler imaging (TDI) and Pulmonary venous (PV) flow added to the routine echocardiographic assessment. Patients. 322 patients (age: 70.8+/-9.1 years) were enrolled.
Methods:
Mitral inflow pattern, TDI (Ea: early diastolic velocity) and PV flow was assessed to evaluate diastolic function. Deceleration time of mitral E velocity < 150ms, E/Ea> or =7 and/or S/D< 1 of PV flow indicated elevated filling pressure (EFP). Patients were divided into four groups: no DD, mild DD, moderate DD and severe DD.
Results:
In 63 cases we found no DD, mild DD was present in 150 cases, moderate DD in 86 cases and severe DD in 23 cases. Compared with patients without DD, the Ea was decreased in mild and moderate DD (14.8+/-2.3 vs 12.2+/-2.4 cm/s, p<0.001; vs 13.3+/-2.6 cm/s, p=0.005). Normal mitral inflow pattern was found in 149 patients, 86 of them had EFP (58%).
Conclusions:
One third of elderly hypertensive patients with preserved systolic function had moderate-to-severe asymptomatic DD. More than half of the patients had EFP with normal mitral inflow pattern.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)