Endoscopists' estimation of size should not determine surveillance of colonic polyps
S J Moug1, N Vernall, J Saldanha
1Department of General Surgery, Crosshouse Hospital, Kilmarnock, Scotland. susanmoug@nhs.net
Objective:
Current British Society of Gastroenterology guidelines use adenomatous polyp size as one of the key factors in determining polyp follow-up. This study aimed to compare polyp size assessment by colonoscopists and pathologists before and after fixation to determine the optimal method for measurement.
Method:
Thirty-five colorectal polyps were found during pre-arranged colonoscopies in one centre. Polyp size was measured to the nearest 1 mm by three different methods: 1. by the endoscopist at colonoscopy; 2. by the pathologist fresh, following removal; 3. by the pathologist fixed, following fixation. The endoscopist and the pathologist were blinded to each other's measurements.
Results:
Seventeen men, eighteen women with mean age of 66.2 years (SD: 9.4, range: 38.7-85.5) underwent polypectomy/s with all polyps removed intact. Polypectomies were performed by consultants (43%), nurse specialists (34%) and specialist registrars (23%). The median size (mm) of polyps measured were endoscopically, 6.5 (2-25 mm); fresh specimen 7.0 (4-28 mm) and fixed 7.0 (4-28 mm). Endoscopic measurements were significantly lower than that of fresh and fixed sizes (P < 0.001 and P = 0.003 respectively), with poor correlation [correlation of variance (CV): 21.0% and intraclass correlation coefficient (ICCC): 0.841 for endoscopic and fresh measurements; CV: 21.1% and ICCC: 0.838 for endoscopic and fixed measurements]. There was no statistical difference between fresh and fixed specimen measurements (P > 0.05; CV: 4.2%, ICCC: 0.974). In three patients, the endoscopic measurement was < 1 cm in polyps that were found to be >or= 1 cm on pathological measurement.
Conclusions:
Endoscopists consistently underestimated polyp size. Fixation had no effect on polyp size. Pathologists' measurement of polyp size on fixed specimens should determine the need for further colonoscopic follow-up.
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures III: Video Capsule Endoscopy
Urologic Endoscopic Procedure: Cystoscopic Examination
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...