Related Experiment Video
Updated: Jun 22, 2026

Microscopy Techniques for Interpreting Fungal Colonization in Mycoheterotrophic Plants Tissues and Symbiotic Germination of Seeds
Published on: May 17, 2022
Compositional contrast of uncoated fungal spores and stained section-face by low-loss backscattered electron imaging
1National Instrumentation Center for Environmental Management, Seoul National University, Seoul 151-921, Republic of Korea. kiwoo@snu.ac.kr
Abstract:
Comparative surface imaging was performed on uncoated fungal spores and stained section-face by field emission scanning electron microscopy with an in-column energy-selective backscattered electron detector. Epoxy resin thin sections (ca. 200 and 500 nm thick) of the osmicated and uranyl acetate/lead citrate-stained fungus were examined with the microscope. Topographical contrast was evident in secondary electron imaging by either a below-lens or an in-lens detector. Meanwhile, low-loss backscattered electron images showed mainly compositional contrast at low accelerating voltages (mostly below 1 kV). With attenuated topographical contrast, several different electron densities could be detected, exhibiting several levels of electron density even on a flat plane of spines. Minute differences in topography on epoxy resin sections as seen by secondary electron imaging represented the periphery of the fungal spores and hyphae. On the other hand, the compositional contrast could be retrieved from stained section-face in low-loss BSE imaging, revealing subcellular entities after contrast inversion. The resolution of low-loss BSE imaging was sufficient to resolve plasma membrane, and various types of vacuoles and vesicles. These results suggest that low-loss backscattered electron imaging could potentially provide compositional information to resolve surface chemical features of uncoated microbial cells and stained section-face with heterogeneous surface compositions.
Related Concept Videos
Preparation of Samples for Electron Microscopy
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Differential Staining Technique
Immunogold Electron Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Transmission Electron Microscopy

