Related Experiment Video
Updated: Jun 22, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Comprehensive analysis of pulmonary function Test (PFT) changes after stereotactic body radiotherapy (SBRT) for stage
Kevin L Stephans1, Toufik Djemil, Chandana A Reddy
1Department of Radiation Oncology, Taussig Cancer Center, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA. stephak@ccf.org
Background:
To assess for variables predicting pulmonary function test (PFT) changes after stereotactic body radiotherapy (SBRT) for medically inoperable stage I lung cancer.
Methods:
We reviewed 92 consecutive patients undergoing SBRT for stage I lung cancer between February 2004 and August 2007. A total of 102 lesions were treated using prescriptions of 20 Gy x 3 (n = 40), 10 Gy x 5 (n = 56), and 5 Gy x 10 (n = 6). Institutional practice was 10 Gy x 5 before March 1, 2006 before changing to 20 Gy x 3 to conform to RTOG 0236 unless otherwise dictated clinically.
Results:
Median pretreatment forced expiratory volume at 1 second (FEV1) was 1.21 liter (50% of predicted) and median diffusion capacity to carbon monoxide (DLCO) was 56.5. There was no significant overall change in PFT's after SBRT. Individual patients experienced both substantial improvements and declines (10% declined at least 14% predicted FEV1% and 19% predicted DLCO). The mean change in FEV1 was -0.05 liter (range, -0.98 to +1.29 liter; p = 0.22) representing -1.88% predicted baseline FEV1 (range, -33 to + 43%; p = 0.62). DLCO declined 2.59% of predicted (range, -37 to +33%; p = 0.27). Conformality index, V5 and V10 were associated with individual patient changes in FEV1% (p = 0.033, p = 0.0036, p = 0.025, respectively), however, correlations were small and overall treatment dose did not predict for changes (p = 0.95). There was no significant difference in FEV1 (p = 0.55) or FEV1% (p = 0.37) changes for central versus peripheral locations. No factors predicted for individual changes in DLCO. Patients with FEV1% below the median of the study population had significantly longer overall survival (p = 0.0065). Although patients dying of cardiac disease died earlier than those dying of other causes, FEV1% below median was not associated with a lower risk of dying of cardiac disease or with lower Charlson comorbidity index.
Conclusions:
(1) SBRT was well tolerated and PFT changes were minimal. (2) Central lesions were safely treated with 50 Gy.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

