Related Experiment Video
Updated: Jun 22, 2026

Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
Fluid temperatures during arthroscopic subacromial decompression using a radiofrequency probe
Howard Davies1, Henry Wynn-Jones, Thomas De Smet
1Department of Trauma and Orthopaedic Surgery, Ipswich Hospital, Heath Road, Ipswich IP4 5PD, UK. howarddavies@doctors.org.uk
Abstract:
Our aim was to investigate the temperatures reached in the subacromial space during radiofrequency ablation of the subacromial bursa, in order to see if the probes generate sufficiently high temperatures to cause chondrolysis of the articular surfaces in the glenohumeral joint. We recorded the maximum temperatures in the subacromial space during arthroscopic subacromial decompression on 30 consecutive patients using a sterile digital temperature probe (Series 400, DeRoyal, TN, USA). Both the mean (27.8 degrees C) and maximum (41.8 degrees C) temperatures reached were below the experimental thresholds for chondrocyte damage. At 2 year follow-up we report no cases of chondrolysis or other complications related to the radiofrequency probes and conclude that given the relatively low maximum temperatures generated by the probes the risk of adverse effects is minimal.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Decreased Body Temperature
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...