Related Experiment Video
Updated: Jun 22, 2026

Comparative Analysis of Human Growth Hormone in Serum Using SPRi, Nano-SPRi and ELISA Assays
Published on: January 7, 2016
Arginine and clonidine stimulation tests for growth hormone deficiency revisited--do we really need so many samples?
Lili Muster1, David H Zangen, Rafael Nesher
1Department of Pediatrics, Ein Kerem Campus, Hadassah Hebrew University Medical Center, Jerusalem, Israel.
Abstract:
Growth hormone (GH) reserve is defined biochemically by the peak serum concentration after stimulation with a known secretagogue. Arginine and clonidine stimulation tests are currently performed with 5 timed blood samples. We evaluated the diagnostic utility of taking fewer samples by retrospectively analyzing 289 tests (202 arginine and 87 clonidine) performed in a single hospital. 123/202 (60.9%) arginine tests and 46/87 (52.9%) clonidine tests had at least one sample above 10 ng/ml. These were defined as negative for GH deficiency and studied further. For arginine tests, three samples taken at 0', 45' and 90' would have provided an acceptable false positive rate of 4.5%. For clonidine tests, two samples taken at 60' and 90' provided a false positive rate of 4.3%. Addition of either a 0' or 120' sample further reduced the false positive rate to 2.2%. Both the arginine and clonidine stimulation tests can be reliably performed with fewer samples.
