New and low-cost auto-algometry for screening hypertension-associated hypoalgesia
Andrea Viggiano1, Nicola Zagaria, Maria Beatrice Passavanti
1Department of Study of Institutions and Territorial Systems, University of Naples Parthenope, Napoli, Italy. andrea.viggiano@uniparthenope.it
Objective:
The aim of the present work was to measure the pain threshold in hypertensive patients with a new auto-algometry method.
Design And Setting:
Auto-algometry consists of asking the subjects to push their fingers against a fixed round-tip needle until they feel a pain sensation. An electronic force transducer permits the measurement of the force applied by the subjects and storage of the data on a personal computer. Eight tests are performed twice on each subject on the tip and back of four fingers. For each test, the maximal applied force (grams) is defined as pain threshold. The overall discomfort during the entire procedure is reported by the subjects on a 0 (no discomfort) to 10 (intolerable pain) scale.
Patients And Interventions:
A group of hypertensive patients (n = 22) and a group of normotensive subjects (n = 22) underwent the auto-algometry examination.
Results:
The pain threshold was higher in hypertensive patients compared with normotensive subjects. All discomfort scores referred by the subjects fell within the 4-6 range.
Conclusion:
The data obtained from this study indicate that the auto-algometer as described here can detect hypoalgesia associated with hypertension.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Hypertension III: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation