Related Experiment Video
Updated: Jun 22, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Simultaneous determination of 15 steroidal oral contraceptives in water using solid-phase disk extraction followed by
Li Sun1, Wei Yong, Xiaogan Chu
1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085, China.
Abstract:
A rapid, accurate and sensitive method for simultaneous determination of 15 steroidal hormones including four estrogens (estrone, 17beta-estradiol, 17alpha-ethynylestradiol, estriol) and eleven progestogens (17beta-estradiol-3-benzoate, 19-norethindrone, gestodene, levonorgestrel, medroxyprogesterone, cyproterone acetate, megestrol-17-acetate, progesterone, norethindrone acetate, chlormadinone-17-acetate, and hydroxy progesterone caproate) in environmental waters was developed by coupling solid-phase disk extraction (SPDE) to ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with electrospray ionization. Among three types of extraction tested (C(8) SPDE, C(18) SPDE and C(18) SPE), the most satisfactory result was achieved using C(18) SPDE for its satisfactory recovery (75.6 to 101.4%) and short extraction time (15 min for 1L deionised water). The validity of this method was investigated and good analytical performance for all the analytes was obtained, including low limits of method detection (0.5-3.4 ng/L) and excellent linear dynamic range (1.0-50.0 ng/L). The method was applied to determine the steroidal hormones in 10 environmental waters including tap water, river water, lake water and waste water in Beijing. No progestogen was detected in all samples and estrone, estriol, 17alpha-ethynylestradiol were found in most samples at levels between 1.8 and 127.9 ng/L.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors