[Heart sound measurement and analysis system with a stethoscope]
Haibin Wang1, Zhongwei Jiang, Xiucheng Dong
1School of Electrical and Information Engineering, Xihua University, Chengdu 610039, China. ddwang.kr987@yahoo.com.cn
Abstract:
This paper is composed with the cardiac sound measurement and analysis system for in-home use of heart abnormality monitoring. The heart sound acquiring system is composed of a traditional chest-piece, earphone, microphone, and IC recorder. The recorded data is transmitted to a computer by USB interface for analysis based on the cardiac sound characteristic waveform (CSCW) method, which is extracted from an analytical model of single degree-of-freedom (SDOF). Furthermore, the characteristic parameters [T1, T2, T11, T12] are defined by the time intervals between the crossed points of the CSCW and a threshold value (THV), which are related to the first sound and the second sound and are used for discriminating normal and abnormal heart sounds. Also, an easy-understanding graphical representation for these parameters is considered, so that, even for an inexperienced user, he or she is able to monitor his or her cardiac status easily. Finally, a case study on the abnormal/normal cardiac sounds is demonstrated to validate the usefulness and efficiency of this proposed system and the cardiac sound characteristic waveform method.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure