Related Experiment Video
Updated: Jun 22, 2026

07:42
Rapid Repetition Rate Fluctuation Measurement of Soliton Crystals in a Microresonator
Published on: December 15, 2021
Analysis of replica pulses in femtosecond pulse shaping with pixelated devices
Optics Express
|June 9, 2009
Abstract:
We present a detailed analysis of commonly encountered waveform distortions in femtosecond pulse shaping with pixelated devices, including the effects of discrete sampling, pixel gaps, smooth pixel boundaries, and nonlinear dispersion of the laser spectrum. Experimental and simulated measurements are used to illustrate the effects. The results suggest strategies for reduction of some classes of distortions.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
Reconstruction of Signal using Interpolation
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
Aliasing
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Rectangular and Triangular Pulse Function
The unit rectangular pulse function is mathematically represented by a rectangular function centered at the origin with a height of one unit. This function is defined by two parameters: T, which specifies the center location of the pulse along the time axis, and τ, which determines the pulse duration.
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,

