A local exhaust ventilation system to reduce airborne ribavirin concentrations
D Matlock1, R M Buchan, M Tillery
1Exxon Chemical Americas, Medicine & Environmental Health Dept., Houston, TX 77079.
Abstract:
A local exhaust hood was designed and built to capture and contain aerosol emissions of ribavirin during drug administration. The newly designed over-the-head hood is similar to the single hood currently used to administer the drug. This new hood was surrounded by an exhaust plenum to form a compound hood configuration. The exhaust plenum was connected to a filtered local exhaust air system to remove the waste aerosol. The compound hood and local exhaust ventilation system were evaluated for leak rate and inside hood aerosol concentration as a function of exhaust flow rates. This hood reduced the leak rate from an average of 98% with the traditional head hood to an average of less than 1% with the compound hood with exhaust port. The compound hood did not perform quite as well when not in use (set aside during infant caretaking) with the nebulizer remaining on. The leak rate was found to increase from an average of less than 1% to an average of 12% when trials were conducted that used a doll as a simulated patient versus trials without a doll, respectively. As regards therapeutic dose inside the hood, the system's performance may lead to an 18% to 25% decrease in inside hood concentration of aerosol entering the hood. Optimum hood operating parameters were identified. An exhaust flow rate in the range from 1.0 Lpm below to 1.0 Lpm above inlet flow rate from the small particle aerosol generator (SPAG nebulizer) reduced the leak rate to an average of less than 1%.(ABSTRACT TRUNCATED AT 250 WORDS)
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Common Respiratory Disorders
Upper respiratory disorders impact the airways above the vocal cords, encompassing areas like the nose, sinuses, and throat. Various conditions fall under this category, including the common cold and allergic rhinitis. These disorders can stem from several causes,...
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Pulmonary Tuberculosis V
Latent tuberculosis infection occurs when TB bacteria are present in a person's body, but are not causing illness or symptoms. It is not contagious, and preventive treatment is crucial to avoid the progression...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Respiratory Syncytial Virus Disease