Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
UV–Vis Spectroscopy: Molecular Electronic Transitions01:16

UV–Vis Spectroscopy: Molecular Electronic Transitions

In Ultraviolet–Visible (UV–Vis) spectroscopy, the absorption of electromagnetic radiation is used to probe the electronic structure of molecules. This technique provides insights into molecular electronic transitions, particularly the movement of electrons between different molecular orbitals. Radiation is absorbed if the energy of the electromagnetic radiation passing through the molecule is precisely equal to the energy difference between the excited and ground states. During this process,...
Interaction of EM Radiation with Matter: Spectroscopy01:12

Interaction of EM Radiation with Matter: Spectroscopy

Electromagnetic (EM) radiation can be considered an oscillating electric and magnetic field propagating through a medium that can interact with matter in its path. The electric field in the radiation can interact with electrical charges in the atoms or molecules in the matter. On the other hand, the magnetic field can interact with the magnetic field in the atomic nucleus. The study of the interaction between electromagnetic radiation and matter is termed spectroscopy. Spectroscopy is the study...
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Beyond resorption: targeting osteoclast fusion and polarization to restore balanced bone remodeling.

Frontiers in pharmacology·2026
Same author

How Proton Incorporation Reshapes Lattice Dynamics In BaSnO<sub>3</sub>-Type Proton Conductors.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Clinical Significance of V4R ST-Segment Elevation on a Synthesized 18-Lead Electrocardiogram in Patients With Anterior ST-Segment Elevation Myocardial Infarction.

Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions·2026
Same author

<sup>119</sup>Sn Element-Specific Phonon Density of States of BaSnO<sub>3</sub>.

Crystals·2026
Same author

Bacterial collagenase harnesses collagen geometry for processive cleavage.

Nature communications·2026
Same author

FPGA-accelerated streaming data reduction achieving an average compression ratio over 8000 in a 17.4 kHz, 840 kpixel CITIUS detector for quasi-elastic gamma-ray scattering.

Journal of synchrotron radiation·2026

Related Experiment Video

Updated: Jun 22, 2026

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet (VUV) Synchrotron Radiation
09:53

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet (VUV) Synchrotron Radiation

Published on: October 30, 2012

Synchrotron-radiation-based Mössbauer spectroscopy.

Makoto Seto1, Ryo Masuda, Satoshi Higashitaniguchi

  • 1Research Reactor Institute, Kyoto University, Kumatori-cho, Sennan-gun, Osaka 590-04, Japan.

Physical Review Letters
|June 13, 2009
PubMed
Summary

A novel synchrotron radiation (SR) method enables Mössbauer spectroscopy for previously inaccessible nuclides. This advanced technique successfully measured the 73Ge spectrum, expanding Mössbauer analysis capabilities.

More Related Videos

Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
08:55

Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses

Published on: June 7, 2018

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
10:12

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples

Published on: June 19, 2018

Related Experiment Videos

Last Updated: Jun 22, 2026

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet (VUV) Synchrotron Radiation
09:53

Molecular Beam Mass Spectrometry With Tunable Vacuum Ultraviolet (VUV) Synchrotron Radiation

Published on: October 30, 2012

Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
08:55

Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses

Published on: June 7, 2018

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples
10:12

Synchrotron X-ray Microdiffraction and Fluorescence Imaging of Mineral and Rock Samples

Published on: June 19, 2018

Area of Science:

  • Nuclear Physics
  • Materials Science
  • Spectroscopy

Background:

  • Mössbauer spectroscopy is a powerful technique for studying materials.
  • Traditional methods using radioisotope (RI) sources have limitations in nuclide applicability.
  • Certain Mössbauer nuclides cannot be analyzed with existing RI-based techniques.

Purpose of the Study:

  • To develop a new method for Mössbauer absorption spectra using synchrotron radiation (SR).
  • To expand the range of measurable Mössbauer nuclides beyond the limitations of radioisotope (RI) sources.
  • To demonstrate the feasibility of SR for advanced Mössbauer spectroscopy.

Main Methods:

  • Utilized synchrotron radiation (SR) as a source for Mössbauer absorption spectroscopy.
  • Applied the SR-based method to measure the Mössbauer spectrum of the 68.752 keV excited state of 73Ge.
  • Compared the capabilities of SR sources with traditional RI sources for Mössbauer measurements.

Main Results:

  • Successfully developed a new method for obtaining Mössbauer absorption spectra using SR.
  • The SR method is applicable to a wider range of Mössbauer nuclides compared to RI sources.
  • The Mössbauer spectrum of 73Ge, previously unmeasurable with RI sources, was successfully obtained using SR.

Conclusions:

  • Synchrotron radiation (SR) offers a versatile and powerful alternative for Mössbauer spectroscopy.
  • The developed SR method overcomes limitations of RI sources, enabling advanced measurements.
  • This technique significantly broadens the scope of Mössbauer spectroscopy applications in various scientific fields.