Quantitation of serum monoclonal proteins: relationship between agarose gel electrophoresis and immunonephelometry
David L Murray1, Euijung Ryu, Melissa R Snyder
1Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, USA.
Background:
Previous comparisons of monoclonal protein quantification identified a bias between serum protein electrophoresis (SPEP) and immunonephelometry (NEPH).
Methods:
We reviewed data from 2845 patients in whom a single sample provided a gamma fraction M-spike by SPEP, a heavy chain isotype by immunofixation electrophoresis (IFE), and an Ig quantification by NEPH. We examined the relationship between SPEP and NEPH. Selected sera with high monoclonal protein concentrations were diluted and reassessed.
Results:
For all isotypes, the relationship between SPEP and NEPH was best fitted with cubic curves. We determined the concentrations of each isotype that fitted a linear relationship. IgA had the best correspondence (slope 0.92, 95% CI 0.87-1.02), whereas IgM demonstrated a systematic bias of higher values by NEPH (slope 1.80, 95% CI 1.68-1.92). IgG demonstrated a nonlinear relationship between SPEP and NEPH, with a linear region <19.2 g/L having a slope of 0.83 (95% CI 0.79-0.89) and a second linear region having a slope of 1.47 (95% CI 1.39-1.53) at higher concentrations. Dilutions of high-concentration IgG monoclonal proteins were linear by NEPH and nonlinear by SPEP.
Conclusions:
There are systematic differences in the quantification of monoclonal IgM and IgG by SPEP and NEPH. The bias in IgM is from NEPH overestimation. The nonlinearity of SPEP at high monoclonal IgG concentrations may obscure changes in plasma cell populations. Clinicians should be made aware of the biases and nonlinearity in these tests to make proper conclusions regarding treatment response.
More Related Videos
10:50Purification and Analytics of a Monoclonal Antibody from Chinese Hamster Ovary Cells Using an Automated Microbioreactor System
Published on: May 1, 2019
06:39Author Spotlight: Characterization of Low-Affinity Protein Interactions in Solution Using MassFluidix Technology
Published on: January 26, 2024
Related Concept Videos
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
