Monte Carlo modeling of cascade gamma rays in (86)Y PET imaging: preliminary results
Xuping Zhu1, Georges El Fakhri
1Radiology Department, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, MA, USA. xzhu4@Partners.org
Abstract:
(86)Y is a PET agent that could be used as an ideal surrogate to allow personalized dosimetry in (90)Y radionuclide therapy. However, (86)Y also emits cascade gamma rays. We have developed a Monte Carlo program based on SimSET (Simulation System for Emission Tomography) to model cascade gamma rays in PET imaging. The new simulation was validated with the GATE simulation package. Agreements within 15% were found in spatial resolution, apparent scatter fraction (ratio of coincidences outside peak regions in line source sinograms), single and coincidence statistics and detected photons energy distribution within the PET energy window. A discrepancy of 20% was observed in the absolute scatter fraction, likely caused by differences in the tracking of higher energy cascade gamma photons. On average, the new simulation is 6 times faster than GATE, and the computing time can be further improved by using variance reduction techniques currently available in SimSET. Comparison with phantom acquisitions showed agreements in spatial resolutions and the general shape of projection profiles; however, the standard scatter correction method on the scanner is not directly applicable to (86)Y PET as it leads to incorrect scatter fractions. The new simulation was used to characterize (86)Y PET. Compared with conventional (18)F PET, in which major contamination at low count rates comes from scattered events, cascade gamma-involved events are more important in (86)Y PET. The two types of contaminations have completely different distribution patterns, which should be considered for the corrections of their effects. Our approach will be further improved in the future in the modeling of random coincidences and tracking of high-energy photons, and simulation results will be used for the development of correction methods in (86)Y PET.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography