Determination of trace elements in biological samples by inductively coupled plasma mass spectrometry with
Bruno Lemos Batista1, Denise Grotto, Jairo Lisboa Rodrigues
1Departamento de Análises Clínicas, Toxicológicas e Bromatológicas, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, FCFRP, USP, Avenida do Café, s/n, Monte Alegre, 14040-903, Ribeirão Preto, SP, Brazil.
Abstract:
A simple method for sample preparation of biological samples for trace elements determination by inductively coupled plasma mass spectrometry (ICP-MS) is described. Prior to analysis, 75 mg of the biological samples were accurately weighed into (15 mL) conical tubes. Then, 1 mL of 50% (v/v) tetramethylammonium hydroxide (TMAH) solution was added to the samples, incubated at room temperature for 12 h and the volume made up to 10 mL with a solution containing 0.5% (v/v) HNO(3), 0.01% (v/v) Triton X-100 and 10 microg L(-1) of Rh. After preparation samples may be stored at -20 degrees C during 3 days until the analysis by ICP-MS. With these conditions, the use of the dynamic reaction cell was only mandatory for chromium determination. Method detection limits were 0.2145, 0.0020, 0.0051, 0.0017, 0.0027, 0.0189, 0.02, 0.5, 0.1, 0.0030, 0.0043, 0.0066, 0.0009, 0.020, 0.0043, 0.1794, 0.1 microg(-1) for Al, As, Ba, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Pb, Sb, Se, Sr, V and Zn, respectively. Validation data are provided based on the analysis of six certified reference materials (CRMs) purchased from the National Institute of Standards and Technology (NIST) and National Research Council Canada (NRCC). Additional validation was provided by the analysis of brain, kidney, liver and heart samples collected from rats and analyzed by the proposed method and by using microwave digestion.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...