Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

AI-driven digital holographic microscopy for label-free quantitative cellular analysis: toward low-cost and field-deployable platforms.

Biomedical optics expressยท2026
Same author

Morphological investigation of astrocyte brain cells using quantitative phase imaging.

Biomedical optics expressยท2026
Same author

Security authentication and tracking of unmanned moving vehicles with optical ID tags.

Optics expressยท2026
Same author

3D profilometric object detection in turbid water using integral imaging and deep neural networks.

Optics expressยท2026
Same author

Underwater multidimensional metrology in degraded environments with augmented reality devices.

Optics expressยท2026
Same author

Dynamic vision-based underwater optical signal detection system in a degraded environment using multi-dimensional integral imaging and deep learning.

Optics expressยท2026
Same journal

Denoising algorithm of ฮฆ-OTDR systems based on adaptive fractional wavelet transform denoising.

Optics expressยท2026
Same journal

Millisecond photon-to-photon latency and high-speed volumetric projection system for optogenetics.

Optics expressยท2026
Same journal

Polarization-encoded coaxial structured light for high-precision 3D surface profilometry.

Optics expressยท2026
Same journal

Discrete freeform optical design based on collaborative optimization of point cloud and local normals.

Optics expressยท2026
Same journal

Ultrafast ghost imaging with 25 GHz speckle switching and wavelength-division multiplexing.

Optics expressยท2026
Same journal

Atomic vapor cells fabricated by femtosecond laser welding of standard-optical-quality glass.

Optics expressยท2026
See all related articles

Related Experiment Video

Updated: Jun 22, 2026

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
14:09

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

Published on: April 7, 2014

Optically-corrected elemental images for undistorted Integral image display.

Raul Martinez-Cuenca, Amparo Pons, Genaro Saavedra

    Optics Express
    |June 17, 2009
    PubMed
    Summary
    This summary is machine-generated.

    Conventional integral imaging capture uses relay systems causing image distortions. Our new telecentric relay system significantly improves 3D image quality by reducing resolution loss and distortions.

    More Related Videos

    Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
    06:53

    Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−

    Published on: July 27, 2018

    Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
    10:00

    Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles

    Published on: July 5, 2016

    Related Experiment Videos

    Last Updated: Jun 22, 2026

    Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
    14:09

    Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope

    Published on: April 7, 2014

    Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
    06:53

    Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−

    Published on: July 27, 2018

    Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles
    10:00

    Energy Dispersive X-ray Tomography for 3D Elemental Mapping of Individual Nanoparticles

    Published on: July 5, 2016

    Area of Science:

    • Optics and Photonics
    • 3D Imaging Technologies

    Background:

    • Integral Imaging (II) commonly uses relay systems in its capture stage.
    • Conventional relay systems lead to microimage overlap and shift, degrading reconstructed 3D image quality through resolution loss and distortions.

    Purpose of the Study:

    • To propose and demonstrate a novel capture stage architecture for Integral Imaging.
    • To overcome the limitations of conventional relay systems in II.

    Main Methods:

    • Implementation of a telecentric relay system for the capture stage.
    • Experimental validation of the proposed system's performance.

    Main Results:

    • The telecentric relay system effectively mitigates microimage overlap and shift.
    • Significant improvements in the quality of reconstructed 3D images were observed.

    Conclusions:

    • A telecentric relay system offers a superior alternative for the Integral Imaging capture stage.
    • This advancement enhances 3D image fidelity by reducing common artifacts.