Ischial pressure sores: reconstruction using the perforator-based reverse flow musculocutaneous 180 degrees propeller
Rafael G Jakubietz1, Michael G Jakubietz, Danni F Jakubietz
1Department of Trauma, Plastic and Handsurgery, Julius-Maximilian-University of Wuerzburg, Germany. jakubietz_r@klinik.uni-wuerzburg.de
Abstract:
The treatment of pressure sores requires soft tissue reconstruction with thick tissue to provide padding of bony prominences and obliterate dead space. Fasciocutaneous flaps may not provide adequate bulk. Propeller flaps (180 degrees) based on perforators from the gluteal artery may be harvested as a reverse flow musculocutaneous flap including a muscle plug to reconstruct deep cavities. Three patients presenting with deep pressure sores required reconstruction of large cavities. In addition to a regular 180 degrees propeller flap, a muscle plug based on a perforator found in the blade of the propeller was used to add bulk to the flap and obliterate the cavity with well-vascularized tissue. One flap required secondary closure of the donor site due to dehiscence, one hematoma required drainage. All flaps survived completely. No recurrence of osteomyelitis or pressure sores was seen. The 180 degrees propeller flap can be harvested as a reverse flow musculocutaneous flap including a muscle plug in the distal blade. This adds volume which is required to adequately obliterate large cavities in cases of osteomyelitis. This new technique may be useful in other areas as well.