Study of calcium-soy protein interactions by isothermal titration calorimetry and pH cycle

Latha-Selvi Canabady-Rochelle1, Christian Sanchez, Michel Mellema

  • 1Nancy-Université, Institut National Polytechnique de Lorraine, Ecole Nationale Supérieure d'Agronomie et des Industries Alimentaires, Laboratoire d'Ingenierie des Biomolécules, 54505 Vandoeuvre-Lès-Nancy, France. l.canabady@voila.fr

Related Concept Videos

Calmodulin-dependent Signaling01:16

Calmodulin-dependent Signaling

Calmodulin (CaM) is a calcium-binding protein in eukaryotes that controls various calcium-regulated cellular processes. It has four calcium-binding sites that bind calcium to form the calcium-calmodulin ( Ca2+-CaM) complex. GPCR stimulation increases the calcium levels in the cells that bind to CaM and induces a conformational change.
The Ca2+-CaM complex does not have enzymatic activity by itself. Instead, the complex binds downstream target proteins, including membrane proteins or enzymes,...
Calorimetry01:19

Calorimetry

When objects at different temperatures are placed in contact with each other but isolated from everything else, they attain thermal equilibrium. A container that prevents heat transfer in or out is called a calorimeter, and the use of a calorimeter to make measurements is called calorimetry. Generally, these measurements involve heat or specific heat capacity. The term "calorimetry problem" is used for any problem where the specified objects are thermally isolated from their surroundings. An...
Potentiometric Titration: Overview01:31

Potentiometric Titration: Overview

Potentiometric titration is a quantitative analytical technique that determines the concentration of an analyte by measuring the potential difference between the two electrodes in the solution. The endpoint of a potentiometric titration is the point at which there is a significant change in the potential difference. It occurs when the stoichiometric reaction between the analyte and the titrant is complete. The endpoint is usually determined graphically by plotting the measured potential...
Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...
Constant Pressure Calorimetry03:02

Constant Pressure Calorimetry

Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...