Related Experiment Video
Updated: Jun 22, 2026

An Aptamer-based Sensor for Unchelated Gadolinium(III)
Published on: January 9, 2017
Gadolinium as an alternative contrast agent for therapeutic ERCP in the iodine-allergic patient
1Medical University of South Carolina, Charleston, South Carolina 29425-2900, USA. Lawrench@musc.edu
Performance of endoscopic retrograde cholangiopancreatography (ERCP) requires an intraductal contrast agent. The contrast of choice is an iodine-based agent. The alternatives in patients with a severe allergy to iodinated contrast are limited. We undertook a retrospective review of the success and safety of gadolinium as an alternative radiocontrast agent in patients with allergy to iodine-based contrast in a series of five patients in a tertiary care pancreaticobiliary referral center. The five patients underwent a total of six ERCP procedures using a gadolinium chelate as the radiocontrast agent. ERCP was technically successful in all cases, including pancreatic endotherapy. There were no contrast-related adverse reactions. Gadolinium is concluded to be a reasonable alternative to iodine-based ERCP contrast in selected patients. It provides inferior image quality compared to standard iodine-based contrast but was not technically limiting in our small experience.
Performance of endoscopic retrograde cholangiopancreatography (ERCP) requires an intraductal contrast agent. The contrast of choice is an iodine-based agent. The alternatives in patients with a severe allergy to iodinated contrast are limited. We undertook a retrospective review of the success and safety of gadolinium as an alternative radiocontrast agent in patients with allergy to iodine-based contrast in a series of five patients in a tertiary care pancreaticobiliary referral center. The five patients underwent a total of six ERCP procedures using a gadolinium chelate as the radiocontrast agent. ERCP was technically successful in all cases, including pancreatic endotherapy. There were no contrast-related adverse reactions. Gadolinium is concluded to be a reasonable alternative to iodine-based ERCP contrast in selected patients. It provides inferior image quality compared to standard iodine-based contrast but was not technically limiting in our small experience.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Endoscopic Procedures V: ERCP
Patient...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI