Related Experiment Video
Updated: Jun 22, 2026

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
An enhanced automatic algorithm for estimation of respiratory variations in arterial pulse pressure during regions of
Mateo Aboy1, Cristina Crespo, Daniel Austin
1Electrical Engineering Department, Oregon Institute of Technology (OIT), Portland, OR 97006, USA. mateoaboy@ieee.org
Abstract:
We describe an improved automatic algorithm to estimate the pulse-pressure-variation (PPV) index from arterial blood pressure (ABP) signals. This enhanced algorithm enables for PPV estimation during periods of abrupt hemodynamic changes. Numerous studies have shown PPV to be one of most specific and sensitive predictors of fluid responsiveness in mechanically ventilated patients. The algorithm uses a beat detection algorithm to perform beat segmentation, kernel smoothers for envelope detection, and a suboptimal Kalman filter for PPV estimation and artifact removal. In this paper, we provide a detailed description of the algorithm and assess its performance on over 40 h of ABP signals obtained from 18 mechanically ventilated crossbred Yorkshire swine. The subjects underwent grade V liver injury after splenectomy, while receiving mechanical ventilation, and general anesthesia with isoflurane. All subjects in the database underwent a period of abrupt hemodynamic change after an induced grade V liver injury involving severe blood loss resulting in hemorrhagic shock, followed by fluid resuscitation with either 0.9% normal saline or lactated ringers solutions. Trained experts manually calculated PPV at five time instances during the period of abrupt hemodynamic changes. We report validation results comparing the proposed algorithm against a commercial system (pulse contour cardiac output, PICCO) with continuous PPV monitoring capabilities. Both systems were assessed during periods of abrupt hemodynamic changes against the "gold-standard" PPV, calculated and manually annotated by experts. Our results indicate that the proposed algorithm performs considerably better than the PICCO system during regions of abrupt hemodynamic changes.
Related Concept Videos
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical indicator...
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...

