Effect of biventricular pacing during a ventricular sensed event
Mehmet Kemal Aktas1, Vinodh Jeevanantham, Saadia Sherazi
1Cardiology Department, University of Rochester Medical Center, Rochester, New York, USA. mehmet_aktas@urmc.rochester.edu
Abstract:
Loss of biventricular (BiV) pacing occurs during ventricular sensed events such as frequent ventricular ectopy, nonsustained ventricular tachycardia, and intrinsic atrioventricular nodal conduction, such as in atrial fibrillation. Ventricular sense response (VSR) pacing, a novel cardiac resynchronization therapy pacing strategy, maintains BiV pacing during these sensed ventricular events. Patients who underwent echocardiographic optimization after BiV pacemaker implantation were enrolled, and aortic velocity-time integrals (VTIs) were recorded and compared during intrinsic conduction without pacing, optimized BiV pacing, and intrinsic conduction with VSR pacing alone. Thirty-two patients were enrolled (mean age 68 +/- 11 years, 78% men), with a mean baseline QRS duration of 164 +/- 24 ms and a mean left ventricular ejection fraction of 23 +/- 10%. The mean aortic VTI during intrinsic conduction with VSR pacing was 16.5 +/- 3.6 cm, compared with 15.3 +/- 3.4 cm during intrinsic conduction without pacing (p <0.001). The mean aortic VTI with optimized BiV pacing was 17.3 +/- 3.6 cm, significantly better (p <0.001) compared with intrinsic conduction without pacing. Improvements in aortic VTI were higher with optimized BiV pacing compared with VSR pacing alone (p = 0.02). In the subgroup of patients with left bundle branch block-type activation, the hemodynamic improvements realized with VSR pacing were similar to optimized BiV pacing. Mean aortic VTI improvements with VSR were similar in patients with ischemic and nonischemic cardiomyopathy. In conclusion, a cardiac resynchronization therapy algorithm that maintains BiV pacing during a ventricular sensed event appears to have an aortic VTI response that is significantly better compared with intrinsic conduction without pacing.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrophysiology of Normal Cardiac Rhythm
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...
Dysrhythmias IV: Characteristics of Bradyarrhythmias