Related Experiment Video
Updated: Jun 22, 2026

Fluorescent Lateral Flow Immunoassay Based on Quantum Dots Nanobeads
Published on: June 28, 2024
Simultaneous and sensitive determination of multiplex chemical residues based on multicolor quantum dot probes
Chifang Peng1, Zhuokun Li, Yinyue Zhu
1School of Food Science and Technology, Jiangnan University, 1800 Lihu Road, Wuxi 214122, Jiangsu Province, China.
Abstract:
Biotinylated denatured bovine serum albumin (Bt-dBSA)-coated cadmium telluride (CdTe) quantum dot (QD) conjugates were prepared and used to develop the multiplexed fluoroimmunoassay for the simultaneous determination of five chemical residues. An immune complex was formed using avidin as the bridge to link the Bt-dBSA-QDs with the antibodies. Primarily, individual quantitative determinations of five representative chemical residues were carried out based on the different emission properties of the QDs. Five antibodies were then conjugated with the corresponding QDs to establish the indirect competition fluorescent-linked immunosorbent assay (ic-FLISA) for the simultaneous detection of five chemicals in one well of a microplate. The linear range for dexamethason (DEX) was from 0.33 microg/kg to 10 microg/kg, 0.28 microg/kg to 10 microg/kg for gentamicin (GM), 0.16 microg/kg to 25 microg/kg for clonazepam (CZP), 0.17 microg/kg to 10 microg/kg for medroxyprogesterone acetate (MPA) and 0.32 microg/kg to 25 microg/kg for ceftiofur (CEF), respectively. The limit of detection (LOD) for the simultaneous determination of DEX, GM, CZP, MPA and CEF were as low as 0.13 microg/kg, 0.16 microg/kg, 0.07 microg/kg, 0.06 microg/kg and 0.14 microg/kg, respectively. This detection method was used to analyze samples of pork muscle and the recoveries ranged from 61.3% to 80.3% for DEX and from 74.0% to 87.2% for MPA. Further more, good correlation between the novel ic-FLISA and traditional ELISA was demonstrated during the determination of DEX and MPA residues in real samples. The QD-based protocol described here is less time consuming than the classical method and it may be sufficiently flexible to be used in other systems for the simultaneous multicolor detection of the drugs.
More Related Videos
06:18Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
11:09Multiplex Detection of Bacteria in Complex Clinical and Environmental Samples using Oligonucleotide-coupled Fluorescent Microspheres
Published on: October 23, 2011