Related Experiment Video
Updated: Jun 22, 2026

Local Anesthetic Thoracoscopy for Undiagnosed Pleural Effusion
Published on: November 10, 2023
Pleural electrophysiology variations according to location in pleural cavity
Vasileios K Kouritas1, Chrisi Hatzoglou, Konstantinos I Gourgoulianis
1Department of Physiology, Medical School, University of Thessaly, Larissa, Greece. kouritas@otenet.gr
Abstract:
The aim of the study was to compare the electrophysiology profile of sheep pleura originated from different locations of the pleural cavity with the respective profile in humans. Sheep specimens obtained from upper and lower lung lobes, 1st-4th and 8th-12th rib, ventral-dorsal diaphragm and mediastinum were mounted between Ussing chambers. Human visceral tissues were obtained from patients subjected to lobectomy. Trans-mesothelial resistance (R(TM)) was determined as an indicator of the tissue permeability, while amiloride and ouabain were used as inhibitors of cellular transportation via ion transporters. Control values R(TM) were low in lower lobe visceral, caudal costal parietal and diaphragmatic pleura. Amiloride increased R(TM) at all locations except upper visceral and mediastinum. Higher R(TM) increases were found in caudal parietal and dorsal diaphragmatic samples. Ouabain increased R(TM) of lower visceral, caudal parietal and diaphragmatic pleura but not of mediastinal specimens. Observations made in sheep tissue were comparable with human visceral, parietal and mediastinal regions. In conclusion, results suggest heterogeneity of trans-mesothelial permeability among different pleural locations in sheep as was the case for humans. Thoracic surgeons should consider physiology function of each part of pleural cavity before pleural tissue manipulation. Observations made in sheep may be used to understand human physiology.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Pleural Disorders: Types and Brief Description
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Pleura of the Lungs
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pleural Effusion II: Symptoms and Management
A pleural effusion is the abnormal collection of fluid between the parietal and visceral pleura layers of tissue that form the lining of the lungs and chest cavity. It can occur independently or due to surrounding parenchymal diseases, such as infection, malignancy, or inflammatory conditions.
Clinical Manifestations: