Related Experiment Video
Updated: Jun 22, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Dispersive liquid-liquid microextraction followed by gas chromatography-electron capture detection for determination
1School of Environmental Science and Public Health, Wenzhou Medical College, Wenzhou, China.
Abstract:
A new method of dispersive liquid-liquid microextraction (DLLME) combined with GC-electron capture detection (GC-ECD) was proposed for the extraction and determination of four polychlorinated biphenyls (PCBs) congeners in fish samples. Acetone was used as extraction solvent for the extraction of PCBs from fish samples. The target analytes in the acetone solvent were rapidly transferred to chlorobenzene, which was used as extraction solvent in DLLME procedures. Under the optimum conditions, linearity was obtained in the concentration range from 1.25 to 1250 microg/kg for PCB 52, and 0.25 to 250 microg/kg for PCB 101, 138 and 153. Coefficients of correlation (r2) ranged from 0.9993 to 0.9999. The repeatability was tested by spiking fish samples at 10 microg/kg PCBs, and RSD% (n = 8) varied between 2.2 and 8.4%. The LODs were between 0.12 and 0.35 microg/kg. The enrichment factors of PCBs were from 87 to 123. The relative recoveries of the four PCB congeners for the perch, pomfret and yellow-fin tuna at spiking levels of 10, 20 and 50 microg/kg were in the range of 81.20-100.6%, 85.00-102.7% and 87.80-108.4%, respectively. The results demonstrated that DLLME combined with GC-ECD was a simple, rapid, and efficient technique for the extraction and determination of PCBs in fish samples.
More Related Videos
12:24Laboratory Estimation of Net Trophic Transfer Efficiencies of PCB Congeners to Lake Trout (Salvelinus namaycush) from Its Prey
Published on: August 29, 2014
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.