Multibed needle trap devices for on site sampling and preconcentration of volatile breath biomarkers
Maren Mieth1, Sabine Kischkel, Jochen K Schubert
1Department of Anesthesiology and Intensive Care Medicine, University Rostock, Schillingallee 35, 18057 Rostock, Germany. maren.mieth@med.uni-rostock.de
Abstract:
To facilitate their use in trace gas analysis, the adsorption capacity of needle trap devices (NTDs) was increased by combining three adsorbent materials and increasing total adsorbent amount. The use of 22 gauge needles, application of internally expanding desorptive flow technique without cryofocusation and a new on site alveolar sampling method for NTDs provided sensitivity in the parts per trillion range of VOC concentrations without loosing precision or linearity. LODs were 0.4 ng/L for isoprene, 0.5 ng/L for dimethyl sulphide, 0.9 ng/L for 2-butenal, 1.0 ng/L for hexane, 1.2 ng/L for pentane, 2.3 ng/L for hexanal, 5.3 ng/L for pentanal, and 8.3 ng/L for acetone. R of calibration curves were consistently >0.98. Loss of volatile aldehydes during storage for 7 days was less than 10%. Needle trap devices packed with more than one adsorbent material represent a promising alternative to SPE and SPME for analysis of volatile organic compounds in the low parts per billion/parts per trillion range. Crucial problems of clinical breath analysis concerning sensitivity of analytical methods, limited stability, and decomposition of breath compounds during sampling and storage could be solved.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...