IMA GFATM RNTCP PPM: gearing up to face ground realities

To fight the menace of tuberculosis public-private mix model as being nurtured by Central TB Division and IMA may become an appropriate model for the developing and even for developed countries. IMA had sensitised 12147 private practitioners in five target states in India. Also 592 private practitioners have been trained in District Training Programmes. Frequently asked questions in these sensitisation and District Training Programmes are narrated in this article. The whole of India has been covered under DOTS strategy. Case detection rate of 70% is the key factor for the programme to succeed. CTD is able to reach case detection of new sputum positive (NSP) cases up to 55-60%. IMA is expected to fill the gap to reach magical figures of 70% NSP case detection rate. The risk of active tuberculosis with latent infection is increased 100-fold by HIV infection. Treating HIV and tuberculosis together and initiative of HIV treatment as been elaborated. Immune reconstitution inflammatory syndrome (IRIS) is characterised by a clinical worsening of a known condition or the appearance of a new condition after initiating antiretroviral therapy (ART). Details about IRIS have been narrated in this article.

Related Concept Videos

Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
Transmission Shafts: Problem Solving01:09

Transmission Shafts: Problem Solving

Designing a solid shaft that transmits power from a motor to a machine tool involves a series of calculations to ensure the shaft can withstand the stresses applied by bending moments and torques. First, calculate the torque exerted on the gear, considering the power transmitted by the shaft and its rotational speed. Following this, compute the tangential forces acting on the gears, which directly relate to the torque and the gear radius.
Next, use bending moment diagrams for the shaft to...
Net Torque Calculations01:19

Net Torque Calculations

When a mechanic tries to remove a hex nut with a wrench, it is easier if the force is applied at the farthest end of the wrench handle. The lever arm is the distance from the pivot point (the hex nut in this case) to the person’s hand. If this distance is large, the torque is higher. Only the component of the force perpendicular to the lever arm contributes to the torque. Therefore, pushing the wrench perpendicular to the lever arm is more advantageous. If multiple people apply force to rotate...
Mechanical Efficiency of Real Machines01:14

Mechanical Efficiency of Real Machines

The mechanical efficiency of a machine is a fundamental concept that describes how effectively a machine can convert input work into output work. According to this concept, the efficiency of a machine is equal to the ratio of the output work to the input work. An ideal machine, meaning a machine that has no energy losses, has an efficiency of one. This implies that the input work and the output work are equal.
However, in reality, no machine can be truly ideal, and all of them experience some...
Design of Transmission Shafts01:16

Design of Transmission Shafts

The design of a transmission shaft is governed by two primary specifications: the power it transmits and its rotational speed. These parameters guide the selection of the shaft's material and cross-sectional dimensions, ensuring that the material's maximum shearing stress remains within the elastic limit while transmitting the desired power at the given speed. The system's power is intrinsically linked to the applied torque. The torque applied to the shaft can be calculated by reconfiguring the...
Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...