Related Experiment Video
Updated: Jul 26, 2026

Effective Analysis of Human Exposure Conditions with Body-worn Dosimeters in the 2.4 GHz Band
Published on: May 2, 2018
Personal and home 222Rn and gamma-ray exposure measured in 52 dwellings
N H Harley1, P Chittaporn, M H Roman
1New York University School of Medicine, Department of Environmental Medicine, NY 10016.
Abstract:
A personal 222Rn and gamma-ray detector has been developed. The detector precision is limited only by the Poisson counting error and has a lower limit of detection in this study of 4.5 kBq m-3 h (4 pCi L-1 day). The detector was used in a study of 52 homes in Illinois to measure the personal exposure vs. the simultaneous exposure on all levels of the home. The ratio of personal exposure to basement 222Rn concentration averaged 0.22, with a high degree of scatter (R2 = 31%). The ratio of personal exposure to first floor 222Rn concentration was 0.71, with good correlation (R2 = 85%). In the absence of personal monitoring data, the best estimate of personal exposure appears to be from measurements in the first-floor living space of the home.