Related Experiment Video
Updated: Jun 22, 2026

Digital Printing of Titanium Dioxide for Dye Sensitized Solar Cells
Published on: May 4, 2016
Particle size determination of sunscreens formulated with various forms of titanium dioxide
Anna Wokovich1, Katherine Tyner, William Doub
1Food and Drug Administration, Center for Drug Evaluation and Research, St. Louis, MO 63101, USA. anna.wokovich@fda.hhs.gov
Background:
There has been some apprehension expressed in the scientific literature that nanometer-sized titanium dioxide (TiO(2)) and other nanoparticles, if able to penetrate the skin, may cause cytotoxicity. In light of a lack of data regarding dermal penetration of titanium dioxide from sunscreen formulations, the Food and Drug Administration Center for Drug Evaluation and Research initiated a study in collaboration with the National Center for Toxicology Research using minipigs to determine whether nanoscale TiO(2) in sunscreen products can penetrate intact skin. Four sunscreen products were manufactured.
Method:
The particle size distribution of three TiO(2) raw materials, a sunscreen blank (no TiO(2)) and three sunscreen formulations containing uncoated nanometer-sized TiO(2), coated nanometer-sized TiO(2) or sub-micron TiO(2) were analyzed using scanning electron microscopy (SEM), laser scanning confocal microscopy (LSCM), and X-ray diffraction (XRD) to determine whether the formulation process caused a change in the size distributions (e.g., agglomeration or deagglomeration) of the TiO(2).
Results:
SEM and XRD of the formulated sunscreens containing nanometer TiO(2) show the TiO(2) particles to have the same size as that observed for the raw materials. This suggests that the formulation process did not affect the size or shape of the TiO(2) particles.
Conclusion:
Because of the resolution limit of optical microscopy, nanoparticles could not be accurately sized using LSCM, which allows for detection but not sizing of the particles. LSCM allows observation of dispersion profiles throughout the sample; therefore, LSCM can be used to verify that results observed from SEM experiments are not solely surface effects.
Related Concept Videos
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence