An optimized solenoidal head radiofrequency coil for low-field magnetic resonance imaging

Barbara Blasiak1, Vyacheslav Volotovskyy, Charlie Deng

  • 1Institute of Nuclear Physics, Polish Academy of Sciences, Krakow 31-342, Poland.

Related Concept Videos

Magnetic Field of a Solenoid01:18

Magnetic Field of a Solenoid

A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field due to a solenoid is the vector sum of the magnetic fields due to its individual turns. Therefore, for an ideal solenoid, the magnetic field within the solenoid is directly proportional to the number of turns per unit length and the current. Conversely, the magnetic field outside the solenoid is zero.
Consider a solenoid with 100 turns wrapped around a cylinder of...
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
Solenoids01:17

Solenoids

A solenoid is a conducting wire coated with an insulating material, wound tightly in the form of a helical coil. The magnetic field for a solenoid is the vector sum of the magnetic field due to its individual turns. For an ideal solenoid, the magnetic field inside is almost uniform and parallel to the solenoid axis, while the magnetic field outside the solenoid is nearly zero.
Each turn in a solenoid can be approximated as a circular current carrying coil that generates a dipole moment. The...
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...